The factory settings in firmware up to 1.2152 has a network setting that needs to be adjusted.
Sometimes when pressing pushbutton from a unit (Ex machine, RC4 or RC12) it never reaches the receiver. The reason is that all units in the network answers too fast. The delay E651PPP PRESPONS DELAY is factory set to 400. This can be increased to 8000 witch seems to work well.
This parameter E651PPP is only found in the machine set as master in the network setting E651 MODE. If the parameter does not show, it might be hidden because the menu detail LEVEL E654 is set to level "simple". If so, increase it to level "normal" or "advanced".